Customization: | Available |
---|---|
Material: | Cellulose and Purified Water |
Tensile Strength: | Good |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No |
Item |
Unit |
Value |
||
1 |
Thickness |
um/mil |
8/0.3 |
10/0.4 |
12/0.5 |
2 |
Density |
gr/cm3 |
1,2g/cm3 |
||
3 |
ID |
mm |
75mm |
||
4 |
Breakdown Voltage for one layer |
not less [V] |
8,0µ - 320V |
10,0µ - 380V |
12,0µ - 420V |
5 |
Conductive Particles for 1m2 |
not more |
8,0µ - 200 |
10,0µ - 100 |
12,0µ - 80 |
6 |
Conductivity of water extract |
[µS/cm] |
not more 1:50 module: 12,0 |
||
7 |
Loss Tangent in dry condition at 120ºC |
% |
not more: 0,29% |
||
8 |
Ash content |
% |
not more: 0,35% |
||
9 |
PH |
|
6,0-7,5 |
||
10 |
Moisture conten |
% |
not more: 8,0% |
||
11 |
Machine tear |
N,not less |
8,0µ-12,5 |
10,0µ - 15,6 |
2,0µ - 18,7 |